Type | PCVCB | |
---|---|---|
Rated Voltage | kV | 36 |
Insulation level | kVrms / kVp | 70/170 |
Rated Current | A | 1600 |
Braking Capacity | kA | 26.2 |
Making Capacity | kAp | 65.5 |
Short Time Current (1 or 3 Sec) | kA | 26.2 |
Operating Sequence | O – 0.3 Sec – CO – 3 min – CO | |
Auxiliary Switch Contacts | 8NO + 8NC | |
Spring Charging Motor Power | W | 250 |
Spring Charging Motor Voltage | V | 230V AC, 110V DC, 220V DC |
Closing / Tripping Coil Power | W | 180 |
Closing / Tripping Coil Voltage | V | 24, 30, 48, 110, 220DC |
Opening time | ms | <50 |
Closing time | ms | <100 |
Weight | kGS | 650 |
Up to 11kV | 22kV | 33kV | |||||
---|---|---|---|---|---|---|---|
Indoor | Indoor | Indoor | Indoor | Indoor | |||
Type | A 12 62D | A 12 63G | MYK-12 | MYK-24 | MYK-36 | ||
Rated Voltage | kV | 12 | 12 | 12 | 24 | 36 | |
Insulation level | kVrms / kVp | 28 / 75 | 28 / 75 | 50 / 125 | 50 / 125 | 70 / 170 | |
Rated Current | A | Up to 1250 | 2500 | 3150 | 1250 | 1250 | |
Braking Capacity | kA | 26.2 | 40 | 40 | 26.2 | 26.2 | |
Dimensions (WXDXH) |
mm | 650 x 1670 x 2000 / 800 x 1650 x 2000 |
1000 x 2000 x 2100 | 1100 x 2000 x 2300 | 1100 x 2000 x 2300 | 1500 x2900 x 2400 | |
Degree of Protection | kVrms / kVp | IP4X | IP4X | IP4X | IP4X | IP4X | |
Weight Of Each Cubicle | kG | 800 | 1100 | 1100 | 1100 | 1600 |
Type | 11kV | 22kV | 33kV | ||
---|---|---|---|---|---|
Voltage level |
kV
|
11
|
22
|
33
|
|
Power Range |
–
|
160kVA-4MVA
|
160kVA-4MVA
|
160kVA-2MVA
|
|
Rated Voltage |
kV
|
12
|
24
|
36
|
|
Insulation level |
kVrms / kVp
|
28 / 75
|
50 / 125
|
70 / 170
|
|
Braking Capacity |
kA
|
IP44 for HT and LT panel and IP23 for Transformer compartment | |||
Degree Of Protection |
26.2
|
||||
HT Compartment |
Breaker / LBS / GIS RMU
|
||||
Transformer Type |
Oil field transformer / Cast resin transformer
|
||||
LT Compartment |
As per customer Requirement
|
Type | 11kV | 22kV | 33kV | |||||
---|---|---|---|---|---|---|---|---|
FP62D
|
FP63G
|
FP62D
|
FP63G
|
FP72D
|
FP73D
|
|||
Rated Voltage |
kV
|
12
|
12
|
24
|
24
|
36
|
36
|
|
Insulation level |
kVrms / kVp
|
28 / 75
|
28 / 75
|
50 / 125
|
50 / 125
|
70 / 170
|
70 / 170
|
|
Rated Current |
A
|
1250
|
2500
|
1250
|
2500
|
1600
|
1600
|
|
Braking Capacity |
kA
|
26.2
|
40
|
26.2
|
26.2
|
16
|
26.2
|
|
Making Capacity |
kAp
|
65.5
|
100
|
65.5
|
65.5
|
40
|
65.5
|
|
Short Time Current (1 or 3 Sec) |
kA
|
26.2
|
40
|
26.2
|
26.2
|
16
|
26.2
|
|
Operating Sequence |
O – 0.3 Sec – CO – 3 min – CO
|
|||||||
Auxiliary Switch Contacts |
8NO + 8NC
|
|||||||
Spring Charging Motor Power |
W
|
250
|
||||||
Spring Charging Motor Voltage |
V
|
230V AC, 110V DC, 220V DC
|
||||||
Closing / Tripping Coil Power |
W
|
80
|
||||||
Closing / Tripping Coil Voltage |
V
|
24, 30, 48, 110, 220DC
|
||||||
Weight (approx) |
kG
|
200
|
225
|
200
|
225 | 225 | 250 |
Type | 11kV | 22kV | 33kV | |||
---|---|---|---|---|---|---|
VCB C500 | VRK 12-4 | VRK 24 | VRK 36 | |||
Rated Voltage | kV | 12 | 12 | 24 | 36 | |
Insulation level | kVrms/kVp | 28/75 | 28/75 | 50/125 | 70/170 | |
Rated Current | A | 1250 | 2500 | 1600 | 1600 | |
Braking Capacity | kA | 26.2 | 40 | 40 | 26.2 | |
Making Capacity | kAp | 65.5 | 100 | 100 | 78.75 | |
Short Time Current (1 or 3 Sec) |
kA | 26.2 | 40 | 40 | 26.2 | |
Operating Sequence | O – 0.3 Sec – CO – 3 min – CO | |||||
Auxiliary Switch Contacts | 8NO + 8NC | |||||
Spring Charging Motor Power | W | 250 | ||||
Spring Charging Motor Voltage | V | 230V AC, 110V DC, 220V DC | ||||
Closing / Tripping Coil Power | W | 180 | ||||
Closing / Tripping Coil Voltage | V | 24, 30, 48, 110, 220DC | ||||
Weight (approx) | kG | 150 | 140 | 140 | 360 |