Operating & Supply Conditions

FEATURES VALUES/ STANDARDS
Ambient Temperature -10 to +40°C
Altitude Not exceeding 1000mtrs above mean sea level.
Atmosphere Corrosive& Hazardous,Zone II,Div II,Ign temp–T3,GAS GRP IIA,IIB
Relative Humidity Up to 100%
Voltage 415V±10%, 3 Ph
Frequency 50Hz ±5%
Combined Variation 10%
Duty S1 (continuous)
Service factor 1.0

Execution & Features

FEATURES VALUES/ STANDARDS
Starting DOL up to 100 & Star Delta for 112 above frames
Permissible starts/hr. Cold successive – 4 hot successive – 3 equally spread – 6
Loading at reduced volts 75% Rated volts for 5 minutes.
Insulation / temp.rise Class `F’ / 70°C
Direction of rotation Bi-directional
No. Of leads 3 up to 100 & 6 for frame 112 & above
Connection. Star Up to 90 frame, 6 & 8 pole ratings of 100 frames
Delta 2 & 4 pole ratings of 100 frame & 112 and above all ratings
Degree of protection IP 55
Method of cooling IC 411
T.box position RHS looking from DE (towards DE up to 160)
Bearing life
(90% survival basis)
40,000 working hrs. For direct drive
20,000 working hrs. For belt drive
Vibration Normal class as per IS: 12075
Noise As per IS: 12065
Construction Foot / ‘B’ flange
Frame sizes ‘ePM80 to 160’, ‘eSC180 to 355’.(For ‘B’ flange mounting ratings covered in ‘eSC180M’ to be offered in ‘eVSC180L’ & ratings covered in ‘eSC225S’ to be offered in ‘eVSC225M’)
Shaft extension. Single cylindrical extension as per IS: 1231
Body material Cast iron
T.box material Cast iron
Fan material Aluminium up to 160, cast iron for 180 – 225, mild steel for 250 to 355 Frames
Accessories
Nil
Paint & shade Epoxy base RAL5012
Bearing type
Greasing facility
Pre lubricated sealed Bearing from 80-160. Open type Bearing
from 180. Online greasing facility is for 180 to 355 only